2-83
D_P UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Characteristics
General
Design Directional spool valve
Actuation Hydraulic
Series D1VP*4L D1VP*90 D3DP D4P D9P D11P
Size NG06 NG06 NG10 NG16 NG25 NG32
Weight [kg] 1.3 1.3 3.7 9.0 17.0 66.0
Mounting interface DIN 24340 A06 DIN 24340 A06 DIN 24340 A10 DIN 24340 A16 DIN 24340 A25 DIN 24340 A32
ISO 4401 ISO 4401 ISO 4401 ISO 4401 ISO 4401 ISO 4401
NFPA D03 NFPA D03 NFPA D05 NFPA D07 NFPA D08 NFPA D10
CETOP RP 121-H
Mounting position unrestricted, preferably horizontal
Ambient temperature [°C] -25...+50
MTTF
D
value [years] 150
Hydraulic
Max. operating pressure [bar]
P, A B: 350; P, A B; T: 350; P, A B, T: 350; P, A B, T: 350; P, A B, T: 350; P, A B, T: 350;
T: 140 X, Y: 210 X, Y: 210 X, Y: 350
1)
X, Y: 350
1)
X, Y: 350
1)
Fluid Hydraulic oil in accordance with DIN 51524 / 51525
Fluid temperature [°C] -25 ... +70
Viscosity permitted [cSt] / [mm²/s] 2.8...400
Viscosity recommended [cSt] / [mm²/s] 30...80
Filtration ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7)
Flow max.
* depending on spool, see shift limits
[l/min] 60* 60* 130 300 700 2000
Leakage at 350 bar (per flow path)
* depending on spool
up to 60* up to 60* up to 100* up to 200* up to 800* up to 5000*
Operating pressure (min/max)
* >tank pressure
[bar] 10* / 210 15 /210 15 /210 5 / 350
1)
5 / 350
1)
5 / 350
1)
Pilot volume [cm
3
] 1.2 0.7
Pilot flow [l/min] 10 10
Static / Dynamic
Step response The response times depend on the pilot oil pressure and on the speed of the increase /
decrease of the pilot pressure.
Technical data
D1VP*B*4L D1VP*90
D1VP*C*4L
Direct Operated Directional Control Valves
Series D1VP, D3DP, D4P, D9P, D11P
* with monitor switch: 105 bar
Hydraulically operated directional control valves are
available in 5 sizes:
D1VP*4L NG06 – operated via end caps
D1VP*90 NG06 – operated via end caps and mounting
interface (X, Y)
D3DP NG10 operated via mounting interface (X, Y)
D4P NG16 operated via mounting interface (X, Y)
D9P NG25 operated via mounting interface (X, Y)
D11P NG32 operated via mounting interface (X, Y)
Size NG06 (D1VP) is available in two different designs:
• D1VP*4L for operating pressure >10bar (over tank
pressure) with control ports in the end caps.
• D1VP*90 for operating pressure >15bar with control
ports in the end caps and mounting interface (X, Y).
All other series are operated only via mounting interface
(X, Y).
The shifting time is depending on the pilot pressure. For
safe operation the minimum pilot pressure has to be
ensured in all operating conditions. The maximum pilot
pressure varies from the maximum operating pressure
in some sizes.
2-84
D_P UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Design
series
(not required
for ordering)
Ordering Code
Direct Operated Directional Control Valves
Series D1VP
Directional
control
valve
Size
DIN NG 06
CETOP 03
NFPA D03
2 position spools
Code Spool type
a b
020
026
030
3 position spools
Code Spool type
a 0 b
001
002
004
006
008 *
009 *
3 position spools
Code all 3 position spools
C
3 positions.
Spring offset in position “0“.
Operated in position “a“ or “b“.
Standard
Spool type 008
and 009
E
Operated in
position “a“.
Operated in
position “b“.
2 positions.
Spring offset in position “0“.
F
Spring offset in
position “b“.
Spring offset in
position “a“.
2 positions.
Operated in position “0“.
K
Operated in
position “b“.
Operated in
position “a“.
2 positions.
Spring offset in position “0“.
M
Spring offset in
position “a“.
Spring offset in
position “b“.
2 positions.
Operated in position “0“.
2 position spools
Code Spool position
B
Spring offset in position “b“.
Operated in position “a“.
D
Detent, operated in position
“a“ or “b“. No centre or offset
position.
H
Spring offset in position “a“.
Operated in position “b“.
Pilot port
G1/8
Spool
type
Spool
position
Seals
Code Seals
N NBR
V FPM
Code Pilot port G1/8
4L
High tank pressure,
indirect via pilot spool
90
Direct via X, Y port
or pipe thread G1/8
Hydraulically
operated
Further spool types and styles on request.
* Consider specific spool
position.
PV1D
3-chamber
design
2-85
D_P UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Ordering Code
Direct Operated Directional Control Valves
Series D3DP
Further spool types and styles on request.
Design
series
(not required
for ordering)
Directional
control
valve
Size
DIN NG 10
CETOP 05
NFPA D05
5-chamber
design
2 position spools
Code Spool type
a b
020
026
030
101
3 position spools
Code Spool type
a 0 b
001
002
003
004
005
006
007
008 *
009 *
010
011
014
015
016
021
022
031
032
081
082
102
3 position spools
Code all 3 position spools
C
3 positions.
Spring offset in position “0“.
Operated in position “a“ or “b“.
Standard
Spool type 008 and
009
E
Operated in
position “a“.
Operated in
position “b“.
2 positions.
Spring offset in position “0“.
F
Spring offset in
position “b“.
Spring offset in
position “a“.
2 positions.
Operated in position “0“.
K
Operated in
position “b“.
Operated in
position “a“.
2 positions.
Spring offset in position “0“.
M
Spring offset in
position “a“.
Spring offset in
position “b“.
2 positions.
Operated in position “0“.
2 position spools
Code Spool position
B
Spring offset in position “b“.
Operated in position “a“.
D
Detent, operated in position “a“ or
“b“. No center or offset position.
H
Spring offset in position “a“.
Operated in position “b“.
Pilot oil
supply and
drain external/
external
Spool
type
Spool
position
SealsHydraulically
operated
Code Seals
N NBR
V FPM
* Consider specific spool
position.
PD3D 2
2-86
D_P UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Ordering Code
Direct Operated Directional Control Valves
Series D4P, D9P, D11P
Spool
type
Spool
position
Hydraulically
operated
Directional
control
valve
Size
3 position spools
Code all 3 position spools
C
3 positions.
Spring offset in position “0“.
Operated in position “a“ or “b“.
Standard Spool type 9
E
Operated in
position “a“.
Operated in
position “b“.
2 positions.
Spring offset in position “0“.
F
Spring offset in
position “b“.
Spring offset in
position “a“.
2 positions.
Operated in position “0“.
K
Operated in
position “b“.
Operated in
position “a“.
2 positions.
Spring offset in position “0“.
M
Spring offset in
position “a“.
Spring offset in
position “b“.
2 positions.
Operated in position “0“.
R
2)
No centre in
offset position.
No centre in
offset position.
2 positions, detent.
Operated in position “0“ or “b“.
S
2)
No centre in
offset position.
No centre in
offset position.
2 positions, detent.
Operated in position “0“ or “a“.
No center in offset position.
2 position spools
Code Spool position
B
Spring offset in position “b“.
Operated in position “a“.
D
2)
Detent, operated in position “a“ or
“b“. No center or offset position.
H
Spring offset in position “a“.
Operated in position “b“.
Further spool types and position
control on request.
Code Bore Size
4 Ø20mm NG16
9 Ø32mm NG25
11 Ø50mm NG32
1)
Consider specific spool position
2)
Only D4 and D9 available
D P
3 position spools
D4
D9
D11
Code Spool type
a 0 b
1
2
3
4
5
6
7
9
1)
11
14
15
16
21
22
31
32
54
81
82
2 position spools
D4
D9
D11
Code Spool type
a b
20
26
30
2-87
D_P UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Ordering Code
Direct Operated Directional Control Valves
Series D4P, D9P, D11P
Seals
Design
series
(not required
for ordering)
AccessoriesPilot oil
supply and
drain external/
external
Code Seals
N NBR
V FPM
Code Accessories
omit
Standard valve
w/o accessories
7
Pilot choke,
meter-out
8
2)
Stroke adjustment
side B
9
2)
Stroke adjustment
side A
60
Pilot choke,
meter-in
89
2)
Stroke adjustment
side A and B
2
2-88
D_P UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Flow curve
Shift limits
Direct Operated Directional Control Valves
Series D1VPFlow Curve Diagrams / Shift Limits
The flow curve diagram shows the flow versus pressure
drop curves for all spool types. The relevant curve number
for each spool type, operating position and flow direction
is given in the table below.
Position „b“ Position „a“ Position „0“
Spool P->A B->T P->B A->T P->A P->B A->T B->T P->T
001 2 2 2 2
002 1 4 1 4 1 1 5 5 2
004 2 3 2 3 7 7
006 1 4 1 4 7 7
020 4 4 2 3
026 4 4
030 2 3 1 2
P->B A->T P->A B->T P->A P->B A->T B->T P->T
008 4 5 4 5 8
009 5 5 6 7 7
Spool Shift limit [l/min]
001
60
002
004
006
020
030
08
40
09
026 20
All characteristic curves measured with HLP46 at 50°C.
2-89
D_P UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Direct Operated Directional Control Valves
Series D3DPFlow Curve Diagrams
Flow curve
The flow curve diagram shows the flow versus pressure
drop curves for all spool types. The relevant curve number
for each spool type, operating position and flow direction
is given in the table below.
All characteristic curves measured with HLP46 at 50°C.
Spool
Position „b“ Position „a“ Position „0“
P-A B-T P-B A-T P-A P-B A-T B-T P-T A-B
001 4 3 4 3
002 2 4 3 3 2 2 1 2 3 4
003 2 2 4 1 5
004 4 3 3 2 5 5 6
005 1 3 4 2 4
006 2 4 3 3 5 5 6
007 4 2 2 2 2 2 5
010 2 2
011 3 3 2 3 10 10 11
014 2 3 4 2 2 2 5
015 4 2 2 2 4
016 4 2 1 1 4
020 4 4 4 4
026 3 3
030 4 3 3 3
081 6 7 6 7
082 7 7 6 5 11 11 11
101 9 9 9 9
102 2 2 2 1 6 6 3 5 6 6
P-B A-T P-A B-T P-A P-B A-T B-T P-T A-B
008 4 2 5 6 8
009 2 5 2 6 8
Position „b“ Position „a“
Position „0“
P-A B-T A-B P-B A-T A-T
021 3 5 6 4 2
031 3 5 6 4 1 9
P-A B-T P-A P-B A-B B-T
022 5 4 5 2 6
032 5 2 5 2 6 9
2-90
D_P UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Flow Curve Diagrams
Direct Operated Directional Control Valves
Series D4P, D9P, D11P
Spool
Code
Curve number
P-A P-B P-T A-T B-T
1 1 1 4 5
2 1 2 6 4 6
3 1 2 5 6
4 1 1 5 5
5 2 2 3 5
6 1 2 3 6
7 1 1 6 4 5
9 2 9 8 7 10
11 1 1 4 5
14 1 1 6 4 5
15 1 2 4 6
16 2 2 3 5
20 3 5 3 5
21 2 8 2
22 8 2 3
26 3 5
30 2 3 6 7
54 2 3 6 7
D4P
D9P and D11P
Spool
Code
Curve number
P-A P-B P-T A-T B-T
D9 D11 D9 D11 D9 D11 D9 D11 D9 D11
1 3 5 2 5 3 4 5 1
2 2 5 1 5 1 5 3 4 5 1
3 4 2 3 6
4 4 3 3 5
5 1 2 4 5
6 2 2 4 6
7 3 1 7 3 5
9 4 3 8 3 9 2 4 3 10 1
11 3 2 3 5
14 1 2 8 3 5
15 3 3 4 5
16 3 3 4 5
20 6 5 5 5 6 3 8
21 5 10 3
22 10 5 5
26 6 5
30 3 5 2 5 3 4 5 1
54 5 5 4 1
The flow curve diagram shows the flow versus pressure
drop curves for all spool types. The relevant curve number
for each spool type, operating position and flow direction
is given in the table below.
All characteristic curves measured with HLP46 at 50°C.
D4P
D11P
D9P
2-91
D_P UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
Dimensions
Direct Operated Directional Control Valves
Series D1VP
D1VP*90
D1VP*4L
Surface finish
BK375
4x M5x30
DIN 912 12.9
7.6 Nm
±15%
NBR: SK-D1VP-N-87
FPM: SK-D1VP-V-87
Surface finish
BK375
4x M5x30
DIN 912 12.9
7.6 Nm
±15%
NBR: SK-D1VP-N4L-91
FPM: SK-D1VP-V4L-91
46
54
Ø9.5
G1/8
85
137
Ø5.5
22
BA
2-92
D_P UK.INDD RH 06.09.2011
Catalogue HY11-3500/UK
Parker Hannifin Corporation
Hydraulics Group
2
D4P
Direct Operated Directional Control Valves
Series D3DP, D4PDimensions
Surface finish
BK320
4x M10x60
2 x M6x55
DIN 912 12.9
63 Nm ±15%
13.2 Nm ±15%
NBR: SK-D41VW-70
FPM: SK-D41VW-V70
D3DP
Surface finish
BK385
4x M6x40
DIN 912 12.9
13.2 Nm
±15%
NBR: SK-D3DP-42
FPM: SK-D3DP-V42
Ø11
88
121
Ø6.5
30
70
77
A B
92
94
11
134
165
101
63
Ø11
44.5
Stroke
adjustment
A B
B
A